[{"data":1,"prerenderedAt":301},["ShallowReactive",2],{"blog-article-en-two-kinds-of-regulation":3},{"item":4,"translation":165},{"id":5,"title":6,"body":7,"cover":145,"coverAlt":146,"date":147,"description":148,"draft":149,"extension":150,"lang":151,"linkedinUrl":132,"meta":152,"navigation":153,"path":154,"seo":155,"slug":156,"stem":157,"tags":158,"translationKey":162,"updated":163,"__hash__":164},"blog\u002Fblog\u002Fen\u002Ftwo-kinds-of-regulation.md","Two Kinds of Regulation",{"type":8,"value":9,"toc":136},"minimark",[10,14,17,22,33,36,40,55,58,64,68,71,86,89,93,102,111,114,118,121,124,127],[11,12,13],"p",{},"As an electrical engineer, I distinguish between two kinds of regulation. Which brings me to my fourth observation from the October “AI Transformation of Healthcare” conference: regulation.",[11,15,16],{},"During the closing panel, I must have heard five times that regulation is not really a problem. Quite the opposite, it is a benefit; in other fields we would suffer without it. Hard to disagree. It is just that every time, I missed the other side of the coin. If it is not such a problem, how exactly does it not weigh on development, in time or in cost? That answer never came.",[18,19,21],"h2",{"id":20},"technical-regulation-rests-on-physics","Technical regulation rests on physics",[11,23,24,25,32],{},"Technical regulation starts from how electric current acts on the human body and how earthing, insulation and circuit protection keep us safe. A good example is the safety standard for medical electrical equipment, ",[26,27,31],"a",{"href":28,"rel":29},"https:\u002F\u002Fwww.rigelmedical.com\u002Fwp-content\u002Fuploads\u002Fsites\u002F3\u002F2025\u002F04\u002Fa-practical-guide-to-iec-60601-rigel-medical-pdf-62b57fe02e7a1.pdf",[30],"nofollow","EN 60601-1",". Patient leakage current from an ordinary applied part is limited to 100 microamps, or 500 under a single fault. For a part that may come into contact with the heart, the limit is ten times lower, because there even microamps can trigger fibrillation. Protective earth may have at most 0.1 ohm and is tested with a current of 25 amps. A surface that is not meant to heat the patient may reach no more than 41 °C.",[11,34,35],{},"Each of those numbers has a clear reason behind it and is checked with an instrument. Pass or fail. No interpretation, no haggling over wording. And above all, every such requirement directly lowers the chance that someone gets hurt. When the insulation survives the test and the leakage current stays under the limit, the patient is safer. Not on paper, but physically.",[18,37,39],{"id":38},"administrative-regulation-rests-on-processes","Administrative regulation rests on processes",[11,41,42,43,48,49,54],{},"On the other side is what the ",[26,44,47],{"href":45,"rel":46},"https:\u002F\u002Feur-lex.europa.eu\u002Flegal-content\u002FEN\u002FTXT\u002F?uri=CELEX%3A02017R0745-20240709",[30],"MDR"," asks of medical device software. Risk class, quality management system, risk management, software life cycle, clinical evaluation, technical documentation, notified body, post-market surveillance. Under ",[26,50,53],{"href":51,"rel":52},"https:\u002F\u002Fhealth.ec.europa.eu\u002Fsystem\u002Ffiles\u002F2025-06\u002Fmdcg_2019_11_en.pdf",[30],"Rule 11",", software that provides information for diagnostic or therapeutic decisions usually lands in class IIa at least, and with that, almost always in front of a notified body. For software that is supposed to keep improving, this hurts twice: a substantial change to an algorithm that can affect diagnosis or treatment is typically assessed again. Not every update, but precisely the ones that matter.",[11,56,57],{},"None of this has a threshold like 100 microamps. Conformity is shown through documentation and audits. It reduces risk too, only indirectly: because the manufacturer has a process in place, keeps records, checks and takes responsibility.",[59,60],"blog-figure",{"alt":61,"caption":62,"src":63},"Infographic ‘Technical versus administrative regulation’: on the left, a measuring instrument and EN 60601-1 limits such as 100 µA, 10 µA, 0.1 Ω, 4,000 V AC and 41 °C; on the right, a binder and MDR requirements for medical device software, from risk class to post-market surveillance.","Technical regulation is proven by measurement, administrative regulation by documentation and audit. Both have their place; they simply rely on a different kind of evidence.","\u002Fimages\u002Fblog\u002Fregulace\u002Fen\u002Fdva-druhy-regulace.webp",[18,65,67],{"id":66},"what-the-paperwork-costs","What the paperwork costs",[11,69,70],{},"Now let me be quite frank. Every hour and every euro that goes “into paper” is missing from the technical solution. From a better test, a better model, validation with clinicians. And that applies to software too.",[11,72,73,74,79,80,85],{},"The numbers do exist; they just were not mentioned on the panel. In a ",[26,75,78],{"href":76,"rel":77},"https:\u002F\u002Fwww.medtecheurope.org\u002Fwp-content\u002Fuploads\u002F2025\u002F01\u002Fmte_report_ivdr_mdr_2024-v7.pdf",[30],"MedTech Europe survey"," from 2024, manufacturers reported an average of 19.5 months for the quality system assessment and 21.8 months for the technical documentation assessment. Of the cost of getting certified, 90% goes on their own staff’s work; notified body fees make up only 7%. In a ",[26,81,84],{"href":82,"rel":83},"https:\u002F\u002Fhealth.ec.europa.eu\u002Fstudy-supporting-monitoring-availability-medical-devices-eu-market_en",[30],"study for the European Commission"," with data as of October 2025, the total cost of a first product certificate averaged roughly €195,000, with a median of €100,000 and a range from €15,000 to €1.3 million. These are not figures for a single app but averages across the industry. Still, the order of magnitude is a year and a half to two years, and hundreds of thousands of euros.",[11,87,88],{},"In the same survey, almost half of manufacturers had withdrawn at least one device from the EU market since 2021. The most frequently cited reason: revenue does not cover the cost of re-approval. That is not a safer patient. That is a patient the device never reaches.",[18,90,92],{"id":91},"a-disclaimer-to-be-fair","A disclaimer, to be fair",[11,94,95,96,101],{},"Technical regulation has its paperwork as well. EN 60601-1 requires risk management and, for programmable systems, refers to a process standard for software development. Hardware in the higher classes also goes through the same MDR as software. Conversely, software can be measured: the ",[26,97,100],{"href":98,"rel":99},"https:\u002F\u002Fhealth.ec.europa.eu\u002Fsystem\u002Ffiles\u002F2020-09\u002Fmd_mdcg_2020_1_guidance_clinic_eva_md_software_en_0.pdf",[30],"MDCG 2020-1 guidance"," explicitly asks for technical and clinical performance to be demonstrated on data. The difference lies in what actually decides conformity in practice. For current, it is the meter. For software, it is the binder.",[11,103,104,105,110],{},"A telling detail: since June 2026, EN 60601-1 has been ",[26,106,109],{"href":107,"rel":108},"https:\u002F\u002Fhealth.ec.europa.eu\u002Fmedical-devices-topics-interest\u002Fharmonised-standards_en",[30],"harmonised under the MDR",", so meeting it gives a presumption of conformity. The key software life cycle standards are not on that list yet.",[11,112,113],{},"I am not saying administration is pointless, and certainly not that regulation is. Only that administration has a price, and the debate tends to leave it out.",[18,115,117],{"id":116},"who-can-carry-it","Who can carry it",[11,119,120],{},"A large manufacturer absorbs it in the budget. It has a quality department, regulatory specialists and a portfolio to spread the costs across. A small team, or a person who knows the problem from the inside, often stops before they start. And yet it is precisely such people who come up with solutions a large manufacturer cannot see from a distance.",[11,122,123],{},"If even part of that energy shifted from paper to measurement, meaning test sets, performance verification and work with clinicians, I do not think safety would suffer. If anything, the opposite.",[11,125,126],{},"So where is the line beyond which administration no longer adds safety, only cost and delay?",[11,128,129,130,135],{},"I published a shorter version on ",[26,131,134],{"href":132,"rel":133},"https:\u002F\u002Fwww.linkedin.com\u002Ffeed\u002Fupdate\u002Furn:li:activity:7526181675031244800\u002F",[30],"LinkedIn"," on 11 November 2026.",{"title":137,"searchDepth":138,"depth":138,"links":139},"",2,[140,141,142,143,144],{"id":20,"depth":138,"text":21},{"id":38,"depth":138,"text":39},{"id":66,"depth":138,"text":67},{"id":91,"depth":138,"text":92},{"id":116,"depth":138,"text":117},"\u002Fimages\u002Fblog\u002Fregulace\u002Fcover.webp","On a workbench under a lamp, a hand with a test probe touches a circuit board in a grey enclosure surrounded by piles of papers, folders and a binder.","2026-11-11","Technical regulation makes things safer directly, because it can be measured. Administrative regulation reduces risk only indirectly and takes time and money that could go into a better solution. Software included.",false,"md","en",{},true,"\u002Fblog\u002Fen\u002Ftwo-kinds-of-regulation",{"title":6,"description":148},"two-kinds-of-regulation","blog\u002Fen\u002Ftwo-kinds-of-regulation",[159,160,161],"AI","Regulation","Digitalization","regulace",null,"haDVDPHbulm1OgLvRHcJI88KoE877D2ol19_1gu-4k4",{"id":166,"title":167,"body":168,"cover":145,"coverAlt":290,"date":147,"description":291,"draft":149,"extension":150,"lang":292,"linkedinUrl":132,"meta":293,"navigation":153,"path":294,"seo":295,"slug":162,"stem":296,"tags":297,"translationKey":162,"updated":163,"__hash__":300},"blog\u002Fblog\u002Fcz\u002Fregulace.md","Dva druhy regulace",{"type":8,"value":169,"toc":283},[170,173,176,180,187,190,194,208,211,216,220,223,236,239,243,251,259,262,266,269,272,275],[11,171,172],{},"Jako elektrotechnik rozlišuji dva druhy regulace. A s tím souvisí čtvrtý postřeh z říjnové konference AI transformace zdravotnictví: regulace.",[11,174,175],{},"Na závěrečném panelu zaznělo snad pětkrát, že regulace v podstatě není problém. Naopak je to přínos, v jiných oborech bychom bez ní trpěli. Nelze nesouhlasit. Jen mi pokaždé chyběla druhá strana mince. Když to není zas tak problém, jak to tedy nezatíží vývoj, časově ani nákladově? Tahle odpověď nezazněla ani jednou.",[18,177,179],{"id":178},"technická-regulace-stojí-na-fyzice","Technická regulace stojí na fyzice",[11,181,182,183,186],{},"Technická regulace vychází z toho, jak proud působí na lidské tělo a jak chrání uzemnění, izolace a jištění. Dobře je to vidět na normě pro bezpečnost zdravotnických elektrických přístrojů ",[26,184,31],{"href":28,"rel":185},[30],". Svodový proud do pacienta má u běžné aplikační části limit 100 mikroampér, při jedné poruše 500. U části, která se dostane do kontaktu se srdcem, je limit desetkrát nižší, protože tam už mikroampéry mohou spustit fibrilaci. Ochranné uzemnění smí mít nejvýš 0,1 ohmu a zkouší se proudem 25 ampér. Povrch, který pacienta nemá hřát, smí mít nejvýš 41 °C.",[11,188,189],{},"Každé z těch čísel má jasný důvod a ověří se přístrojem. Vyhovuje, nebo nevyhovuje. Žádný výklad, žádné dohadování nad formulací. A hlavně: každý takový požadavek přímo snižuje šanci, že se někomu něco stane. Když izolace vydrží zkoušku a svodový proud je pod limitem, pacient je bezpečnější. Ne na papíře, ale fyzikálně.",[18,191,193],{"id":192},"administrativní-regulace-stojí-na-procesech","Administrativní regulace stojí na procesech",[11,195,196,197,202,203,207],{},"Na druhé straně stojí to, co ",[26,198,201],{"href":199,"rel":200},"https:\u002F\u002Feur-lex.europa.eu\u002Flegal-content\u002FCS\u002FTXT\u002F?uri=CELEX%3A02017R0745-20240709",[30],"nařízení MDR"," chce po zdravotnickém softwaru. Riziková třída, systém kvality, řízení rizik, životní cyklus softwaru, klinické hodnocení, technická dokumentace, notifikovaná osoba, dohled po uvedení na trh. Software, který dává informace pro diagnostická nebo terapeutická rozhodnutí, spadne podle ",[26,204,206],{"href":51,"rel":205},[30],"pravidla 11"," zpravidla nejméně do třídy IIa. A tím téměř vždy k notifikované osobě. U softwaru, který se má průběžně zlepšovat, to bolí dvakrát: podstatná změna algoritmu, která může ovlivnit diagnostiku nebo léčbu, se typicky posuzuje znovu. Ne každá aktualizace, ale zrovna ty, na kterých záleží.",[11,209,210],{},"Nic z toho nemá práh jako 100 mikroampér. Shoda se prokazuje dokumentací a auditem. Rizika to taky snižuje, jen nepřímo: tím, že výrobce má nastavený proces, zaznamenává, kontroluje a nese odpovědnost.",[59,212],{"alt":213,"caption":214,"src":215},"Infografika Technická versus administrativní regulace: vlevo měřicí přístroj a limity normy EN 60601-1 jako 100 µA, 10 µA, 0,1 Ω, 4 000 V AC a 41 °C, vpravo šanon a požadavky MDR na zdravotnický software od rizikové třídy po dohled po uvedení na trh.","Technická regulace se prokazuje měřením, administrativní dokumentací a auditem. Obojí má své místo, jen jiný typ důkazu.","\u002Fimages\u002Fblog\u002Fregulace\u002Fdva-druhy-regulace.webp",[18,217,219],{"id":218},"kolik-stojí-papír","Kolik stojí papír",[11,221,222],{},"A teď budu dost upřímný. Každá hodina a každá koruna, která jde „do papíru“, chybí na technickém řešení. Na lepším testu, na lepším modelu, na ověření s lékaři. To platí i pro software.",[11,224,225,226,230,231,235],{},"Čísla přitom existují, jen se o nich na panelu nemluvilo. Výrobci v ",[26,227,229],{"href":76,"rel":228},[30],"průzkumu MedTech Europe"," z roku 2024 uvádějí v průměru 19,5 měsíce na posouzení systému kvality a 21,8 měsíce na posouzení technické dokumentace. Z nákladů na získání certifikace jde 90 % na práci vlastních lidí, poplatky notifikované osobě tvoří jen 7 %. Ve ",[26,232,234],{"href":82,"rel":233},[30],"studii pro Evropskou komisi"," s daty k říjnu 2025 vyšly celkové náklady na první produktový certifikát v průměru zhruba na 195 000 eur, medián na 100 000 eur, s rozptylem od 15 000 eur po 1,3 milionu. Nejsou to čísla za jednu aplikaci, ale průměry napříč oborem. Řádově jde ale o rok a půl až dva roky a stovky tisíc eur.",[11,237,238],{},"Skoro polovina výrobců v tomtéž šetření od roku 2021 stáhla z unijního trhu alespoň jeden prostředek. Nejčastěji uváděný důvod: tržby nepokryjí náklady na nové schválení. To není bezpečnější pacient. To je pacient, ke kterému se prostředek nedostane.",[18,240,242],{"id":241},"disclaimer-aby-to-bylo-fér","Disclaimer, aby to bylo fér",[11,244,245,246,250],{},"I technická regulace má svou dokumentaci. Norma 60601-1 vyžaduje řízení rizik a u programovatelných systémů odkazuje na procesní normu pro vývoj softwaru. Hardware ve vyšších třídách navíc prochází stejným MDR jako software. A naopak software se měřit dá: ",[26,247,249],{"href":98,"rel":248},[30],"pokyn MDCG 2020-1"," výslovně chce doložit technickou a klinickou výkonnost na datech. Rozdíl je v tom, co v praxi o shodě rozhoduje. U proudu měřák, u softwaru složka.",[11,252,253,254,258],{},"Výmluvný detail: EN 60601-1 je od června 2026 ",[26,255,257],{"href":107,"rel":256},[30],"harmonizovaná k MDR",", takže její splnění dává presumpci shody. Klíčové normy pro životní cyklus softwaru v tom seznamu zatím nejsou.",[11,260,261],{},"Netvrdím, že je administrativa zbytečná. A už vůbec ne, že je zbytečná regulace. Jen že administrativa má svou cenu a ta se v diskuzi opomíjí.",[18,263,265],{"id":264},"kdo-to-unese","Kdo to unese",[11,267,268],{},"Velký výrobce to rozpustí v rozpočtu. Má oddělení kvality, regulatorní specialisty a portfolio, přes které se náklady rozloží. Malý tým nebo člověk, který problém zná zevnitř, často skončí dřív, než začne. A právě od takových lidí přitom přicházejí řešení, která velký výrobce z dálky nevidí.",[11,270,271],{},"Kdyby se aspoň část té energie přesunula od papíru k měření, tedy k testovacím sadám, ověřování výkonnosti a práci s lékaři, bezpečnost by podle mě neklesla. Spíš naopak.",[11,273,274],{},"Takže kde je hranice, za kterou administrativa bezpečnost už nezvyšuje, jen zdražuje a zdržuje?",[11,276,277,278,282],{},"Kratší verzi jsem zveřejnil 11. listopadu 2026 na ",[26,279,281],{"href":132,"rel":280},[30],"LinkedInu",".",{"title":137,"searchDepth":138,"depth":138,"links":284},[285,286,287,288,289],{"id":178,"depth":138,"text":179},{"id":192,"depth":138,"text":193},{"id":218,"depth":138,"text":219},{"id":241,"depth":138,"text":242},{"id":264,"depth":138,"text":265},"Ruka s měřicím hrotem se na pracovním stole u lampy dotýká plošného spoje v šedé krabičce, kolem které leží hromady papírů, desek a šanon.","Technická regulace přímo zvyšuje bezpečnost, protože se dá změřit. Administrativní snižuje riziko jen nepřímo a bere čas i peníze, které by šly do lepšího řešení. I u softwaru.","cz",{},"\u002Fblog\u002Fcz\u002Fregulace",{"title":167,"description":291},"blog\u002Fcz\u002Fregulace",[159,298,299],"Regulace","Digitalizace","kMKhu1XrEUogq1VNBifucxCRvQanatEzdrB4AVd6JTg",1795443902284]